通信電纜 網(wǎng)絡設備 無線通信 云計算|大數(shù)據(jù) 顯示設備 存儲設備 網(wǎng)絡輔助設備 信號傳輸處理 多媒體設備 廣播系統(tǒng) 智慧城市管理系統(tǒng) 其它智慧基建產(chǎn)品
上海滬震實業(yè)有限公司
暫無信息 |
閱讀:505發(fā)布時間:2015-5-14
血管細胞粘附分子1(VCAM1)檢測試劑盒
適用生物 Rhesus monkey (Simian,恒河猴)
血管細胞粘附分子1(VCAM1)檢測試劑盒檢測范圍 78.13-5000pg/mL 靈敏度 35pg/mL
樣本類型 Serum, plasma, tissue homogenates and other biological fluids.
實驗時長 4.5h 實驗方法 雙抗夾心法 血管細胞粘附分子1(VCAM1)檢測試劑盒規(guī)格 96T
ELISA Kit for Vascular Cell Adhesion Molecule 1 (VCAM1)
FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!
Organism species Rhesus monkey (Simian)
血管細胞粘附分子1(VCAM1)檢測試劑盒Sample type Serum, plasma, tissue homogenates and other biological fluids.
Format 96-well strip plate
Assay length 4.5 hours
Detection range 78.13-5000pg/mL The standard curve concentrations used for the ELISA’s were 5000pg/mL, 2500pg/mL, 1250pg/mL, 625pg/mL, 312.5pg/mL, 156.25pg/mL, 78.13pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 35pg/mL.
Specificity
This assay has high sensitivity and excellent specificity for detection of Vascular Cell Adhesion Molecule 1 (VCAM1).
No significant cross-reactivity or interference between Vascular Cell Adhesion Molecule 1 (VCAM1) and analogues was observed.
Recovery
Matrices listed below were spiked血管細胞粘附分子1(VCAM1)檢測試劑盒 with certain level of recombinant Vascular Cell Adhesion Molecule 1 (VCAM1) and the recovery rates were calculated by comparing the measured value to the expected amount of Vascular Cell Adhesion Molecule 1 (VCAM1) in samples.
Matrix Recovery range (%) Average(%)
serum(n=5) 91-98 95
EDTA plasma(n=5) 98-105 102
heparin plasma(n=5) 78-92 88
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Vascular Cell Adhesion Molecule 1 (VCAM1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Vascular Cell Adhesion 血管細胞粘附分子1(VCAM1)檢測試劑盒Molecule 1 (VCAM1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Vascular Cell Adhesion Molecule 1 (VCAM1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample 1:2 1:4 1:8 1:16
serum(n=5) 99-105% 80-102% 87-99% 84-98%
EDTA plasma(n=5) 84-101% 97-105% 89-97% 78-97%
heparin plasma(n=5) 98-105% 80-101% 84-95% 97-104%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the血管細胞粘附分子1(VCAM1)檢測試劑盒 whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B 1×120μL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100μL standard or sample to each well. Incubate 2 hours at 37oC;
3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37oC;
4. Aspirate and wash 3 times;
5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
6. Aspirate and wash 5 times;
7. Add 90μL Substrate Solution. Incubate 15-25 minutes at 37oC;
8. Add 50μL Stop Solution. Read at 450nm immediay.
Test principle
The test principle applied in 血管細胞粘附分子1(VCAM1)檢測試劑盒this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Vascular Cell Adhesion Molecule 1 (VCAM1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Vascular Cell Adhesion Molecule 1 (VCAM1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Vascular Cell Adhesion Molecule 1 (VCAM1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Vascular Cell Adhesion Molecule 1 (VCAM1) in the samples is then determined by comparing the O.D. of the 血管細胞粘附分子1(VCAM1)檢測試劑盒samples to the standard curve.
商鋪:http://www.duty-free.cn/st150152/
主營產(chǎn)品:專業(yè)生產(chǎn)ELISA試劑盒,生化試劑,細胞株,分子生物學,生化檢測試劑盒,金標檢測試劑盒,標準品 ,抗體,等產(chǎn)品 .
智慧城市網(wǎng) 設計制作,未經(jīng)允許翻錄必究 .? ? ?
請輸入賬號
請輸入密碼
請輸驗證碼
請輸入你感興趣的產(chǎn)品
請簡單描述您的需求
請選擇省份