avav588con,最近2019中文免费字幕在线观看,欧美一道本一区二区三区,九九热在线观看,经典好看免费AV

行業(yè)產(chǎn)品

  • 行業(yè)產(chǎn)品

上海滬震實業(yè)有限公司


當(dāng)前位置:上海滬震實業(yè)有限公司>技術(shù)文章>補體1q(C1q)檢測試劑盒
技術(shù)文章

補體1q(C1q)檢測試劑盒

閱讀:416發(fā)布時間:2015-5-6

補體1q(C1q)檢測試劑盒

適用生物 Homo sapiens (Human,人)
補體1q(C1q)檢測試劑盒檢測范圍 78.13-5000pg/mL 靈敏度 32pg/mL
樣本類型 Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
實驗時長 4.5h 實驗方法 雙抗夾心法 補體1q(C1q)檢測試劑盒規(guī)格 96T


ELISA Kit for Complement 1q (C1q)
FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!

Organism species Homo sapiens (Human)
Product No. SEA747Hu
Sample type Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Format 96-well strip plate
Assay length 4.5 hours
補體1q(C1q)檢測試劑盒Detection range 78.13-5000pg/mL The standard curve concentrations used for the ELISA’s were 5000pg/mL, 2500pg/mL, 1250pg/mL, 625pg/mL, 312.5pg/mL, 156.25pg/mL, 78.13pg/mL
Sensitivity The minimum detectable dose of this kit is typically less than 32pg/mL.

Specificity
This assay has high sensitivity and excellent specificity for detection of Complement 1q (C1q).
No significant cross-reactivity or interference between Complement 1q (C1q) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Complement 1q (C1q) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement 1q (C1q) in samples.

Matrix Recovery range (%) Average(%)
serum(n=5) 99-105 102
EDTA plasma(n=5) 79-91 82
heparin plasma(n=5) 95-103 99

補體1q(C1q)檢測試劑盒Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement 1q (C1q) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement 1q (C1q) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement 1q (C1q) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Sample 1:2 1:4 1:8 1:16
serum(n=5) 86-101% 88-96% 89-99% 80-102%
EDTA plasma(n=5) 80-90% 92-105% 84-102% 78-91%
heparin plasma(n=5) 94-101% 80-91% 84-93% 91-105%

Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided

補體1q(C1q)檢測試劑盒Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B 1×120μL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1

Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100μL standard or sample to each well. Incubate 2 hours at 37oC;
3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37oC;
4. Aspirate and wash 3 times;
5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
6. Aspirate and wash 5 times;
7. Add 90μL Substrate Solution. Incubate 15-25 minutes at 37oC;
8. Add 50μL Stop Solution. Read at 450nm immediay.
補體1q(C1q)檢測試劑盒Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Complement 1q (C1q). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Complement 1q (C1q). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Complement 1q (C1q), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Complement 1q (C1q) in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 


智慧城市網(wǎng) 設(shè)計制作,未經(jīng)允許翻錄必究 .? ? ? Copyright(C)?2021 http://www.duty-free.cn,All rights reserved.

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準確性和合法性由相關(guān)企業(yè)負責(zé),智慧城市網(wǎng)對此不承擔(dān)任何保證責(zé)任。 溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復(fù)您~