通信電纜 網(wǎng)絡(luò)設(shè)備 無線通信 云計(jì)算|大數(shù)據(jù) 顯示設(shè)備 存儲(chǔ)設(shè)備 網(wǎng)絡(luò)輔助設(shè)備 信號(hào)傳輸處理 多媒體設(shè)備 廣播系統(tǒng) 智慧城市管理系統(tǒng) 其它智慧基建產(chǎn)品
上海滬震實(shí)業(yè)有限公司
暫無信息 |
閱讀:422發(fā)布時(shí)間:2015-4-30
補(bǔ)體3a(C3a)檢測(cè)試劑盒說明書
適用生物 Homo sapiens (Human,人)
檢測(cè)范圍 0.156-10ng/mL 靈敏度 0.061ng/mL
樣本類型 Serum, plasma and other biological fluids
實(shí)驗(yàn)時(shí)長 4.5h 實(shí)驗(yàn)方法 雙抗夾心法 規(guī)格 96T
補(bǔ)體3a(C3a)檢測(cè)試劑盒說明書
ELISA Kit for Complement Component 3a (C3a)
FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!
補(bǔ)體3a(C3a)檢測(cè)試劑盒說明書Organism species Homo sapiens (Human)
Product No. SEA387Hu
Sample type Serum, plasma and other biological fluids
Format 96-well strip plate
Assay length 4.5 hours
Detection range 0.156-10ng/mL The standard curve concentrations used for the ELISA’s were 10ng/mL, 5ng/mL, 2.5ng/mL, 1.25ng/mL, 0.625ng/mL, 0.313ng/mL, 0.156ng/mL
Sensitivity The minimum detectable dose of this kit is typically less than 0.061ng/mL.
補(bǔ)體3a(C3a)檢測(cè)試劑盒說明書Specificity
This assay has high sensitivity and excellent specificity for detection of Complement Component 3a (C3a).
No significant cross-reactivity or interference between Complement Component 3a (C3a) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Complement Component 3a (C3a) and the recovery rates were calculated by comparing the measured value to the expected amount of Complement Component 3a (C3a) in samples.
補(bǔ)體3a(C3a)檢測(cè)試劑盒說明書
Matrix Recovery range (%) Average(%)
serum(n=5) 89-103 92
EDTA plasma(n=5) 99-105 102
heparin plasma(n=5) 97-105 101
Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Complement Component 3a (C3a) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Complement Component 3a (C3a) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Complement Component 3a (C3a) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample 1:2 1:4 1:8 1:16
serum(n=5) 89-101% 79-97% 90-101% 80-102%
EDTA plasma(n=5) 95-102% 90-98% 85-99% 80-101%
heparin plasma(n=5) 85-104% 91-98% 94-104% 84-102%
Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials provided
Reagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B 1×120μL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1
Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100μL standard or sample to each well. Incubate 2 hours at 37oC;
3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37oC;
4. Aspirate and wash 3 times;
5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
6. Aspirate and wash 5 times;
7. Add 90μL Substrate Solution. Incubate 15-25 minutes at 37oC;
8. Add 50μL Stop Solution. Read at 450nm immediay.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Complement Component 3a (C3a). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Complement Component 3a (C3a). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Complement Component 3a (C3a), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Complement Component 3a (C3a) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
商鋪:http://www.duty-free.cn/st150152/
主營產(chǎn)品:專業(yè)生產(chǎn)ELISA試劑盒,生化試劑,細(xì)胞株,分子生物學(xué),生化檢測(cè)試劑盒,金標(biāo)檢測(cè)試劑盒,標(biāo)準(zhǔn)品 ,抗體,等產(chǎn)品 .
智慧城市網(wǎng) 設(shè)計(jì)制作,未經(jīng)允許翻錄必究 .? ? ?
請(qǐng)輸入賬號(hào)
請(qǐng)輸入密碼
請(qǐng)輸驗(yàn)證碼
請(qǐng)輸入你感興趣的產(chǎn)品
請(qǐng)簡單描述您的需求
請(qǐng)選擇省份